Attached SRI calculator+government subsidy application link+Madrid test video


1、 2024 European heatwave crisis and building energy consumption warning

1. Extreme high temperature data upgrade (latest report from the European Union Meteorological Agency)

Europe-heatwave-temperature-map-2024
CountryNumber of Extreme High Temperature Days in 2023Peak Roof Surface TemperatureIncrease in Air Conditioning Energy Consumption
Spain58 days>40 ℃72 ℃ (asphalt shingles)+41%
Italy49 days>38 ℃68 ℃ (concrete tile)+37%
Germany33 days>35 ℃63 ℃ (ceramic tiles)+29%

2. The cost of traditional roof materials during thermal disasters

Munich Commercial Complex Case:
The use of dark asphalt shingles results in:
-Top floor office cooling cost: € 87000/year (exceeding 62%)
-The lifespan of the roof waterproof layer has been shortened to 5 years (normal 15 years)
■ SKW cold roof scheme saving calculation:
After switching to SRI 95 Stone coated metal roof:
-Air conditioning costs reduced by € 32000 per year
-Maintenance cycle extended to 22 years

2、 Core technology of cold roof: from reflective coating to structural innovation

1. Solar Reflectance Index (SRI) Technical Standard

ASTM E1980-11 standard analysis:

SRI = 100×(α - 0.02) + 25.98×ε  
(α: solar absorption rate, ε: thermal emissivity)
SKW cold roof parameters:
α=0.23,ε=0.86 → SRI=95  

EU Mandatory Certification Progress :

NationalMinimum SRI RequirementsEffective TimePenalty Standards
France≥ 822024.09Building permit rejected
Spain≥ 782025.01Energy Efficiency Penalty € 30/m ²
Netherlands≥ 75December 2024Property tax increases by 15%

2. SKW CoolTech ™ Quadruple heat dissipation structure

stone-coated-cool-roof-technology
  1. Reflective layer:
    -Acrylic coating containing ceramic microbeads (reflectivity 92%)
    -Anti pollution treatment: PM2.5 adhesion rate reduced by 67%
  2. Insulation chamber :
    -Air circulation channel design (wind speed ≥ 0.8m/s)
    -Thermal resistance value R=4.5 (EN ISO 6946 standard)
  3. Radiation layer :
    -Aluminum zinc alloy substrate (thermal emissivity 0.86)
    -3D concave convex surface increases heat dissipation area by 38%
  4. Structural layer :
    -Aluminum magnesium coated steel plate (yield strength 550MPa)
    -Patent locking system (wind resistance 5.8kPa)

3、 Actual test data: Madrid vs Berlin Extreme Environmental Challenge

1. Berlin Winter Summer Comprehensive Test, Germany

-Annual Energy Consumption Monitoring Report:

SeasonalTraditional roof energy consumptionSKW roof energy consumptionEnergy saving rate
Summer158kWh/m ²92kWh/m ²41.8%
Winter121kWh/m ²109kWh/m ²9.9%
Conclusion: The comprehensive energy saving rate for the whole year is 31.2%

4、 EU Policy Dividend: Comprehensive Guide to Subsidies and Certification

1. Three step method for applying for government subsidies

  1. Prequalification:
    -View the lists of energy agencies in various countries (such as ADEME in France and BAFA in Germany)
    -SKW products have been pre registered in the EU EPD database (ID # SKW-EPD-2022-0765)
  2. Document Preparation :
    -Required materials:
    ◼ SRI testing report (EN 15804 standard)
    ◼ Installation of enterprise qualification certificates (such as RITE certification in Spain)

2. Authentication Acceleration Channel

-SKW Prefabricated Certification Package Service:

Service ContentStandard CycleSKW Acceleration Cycle
CE Mark (EN 50600)90 days45 days
ACERMI certification in France120 days60 days
Italian CAM certification75 days30 days

5、 Tool Center and Successful Cases

1. Solar Reflectivity Calculator

– Operation Guide :

  1. Access https://skwroof.com/contact-us/
  2. Input parameters:
    -Building GPS coordinates (automatically obtaining local meteorological data)
    -Existing roof material
  3. Obtain:
    -Prediction of investment return rate for energy-saving renovation
    -Recommended models for adaptation (including real-time inventory inquiry)

2. Record of Hamburg Business District Renovation in Germany

– Project Difficulties :

-Restrictions on the protection of historical buildings (prohibition of external insulation layers) -Must meet both DENA energy efficiency standards and aesthetic requirements simultaneously

-SKW Solution:

-Customized matte grey cold roof (SRI 89) -Integrated concealed photovoltaic tile (conversion efficiency 19.8%)

Achievement Data :

IndicatorBefore renovationAfter renovation
Top floor room temperature fluctuation± 8 ℃± 2 ℃
Air conditioning energy consumption€ 163000/year€ 97000/year
Increase in building valuation+18%

6、 Immediate Action: Emergency Response Plan for Heatwave Season

1. Limited time discount package

-2024 Summer Special Service :
✅ Free thermal imaging testing (worth € 800)
✅ Government subsidy application service (reduced by € 1200)
✅ 48 hour express delivery (direct delivery from European bonded warehouse)

2. Technical Consultation Channel

-EU Engineer Direct Connection :
[WhatsApp Consultation]( +86 13153460330 )

[Email Contact] (mailto: business@skywalkerchina.com )

YOUR LANGUAGE

By selecting your language we can ensure you get the best service.