The Load-Bearing Trinity: Composite Action Engineering

Structural Synergy System:

SKW meatl roof Structural Synergy System

Material Science Specifications:

ComponenteEspecificaciónTest StandardSignificance
Steel CoreG550 AZ150ASTM A792/A792MTensile strength 550MPa
Coating WeightAZ150EN 10346150g/m² zinc-aluminum
Yield Strength550 MPaISO 6892-1Deformation resistance

Static Load Performance: Snow & Equipment

Certification Milestones:

  • UL 580 Wind Uplift Class 120
  • ASTM E1592 Severe Weather Rating
  • Passed 300psf static load (exceeds most building codes)
  • FM Global 1-90 Approval

Dynamic Load Resistance: Wind & Impact

Hurricane Simulation Data:

skw metal roof Hurricane Simulation Data

Impact Test Performance:

Impact EnergyResultadoReal-World Equivalent
110 ft-lbsNo rupture2×4 lumber @ 100mph
170 ft-lbsMinor dentHailstone @ 4″ diameter
240 ft-lbsControlled failureTree limb @ 50lbs

Geometric Engineering: The Arch Principle

Profile Design Mechanics:

SKW Profile Design Mechanics

Span Performance Comparison:

SpacingTraditional Tile Max SpanSKW Max Span
16″ o.c.8′-0″14′-6″
24″ o.c.Not recommended10′-9″
32″ o.c.Prohibited8′-4″

Fastening Technology: Hidden Clamp System

Mechanical Interlock Advantage:

Stone coated Metal roof Mechanical Interlock

Resistencia al levantamiento por viento:

Installation TypeFailure PressureMejora
Exposed Fastener90 psfLínea de base
Hidden Clip System300 psf233%

Case Study: Extreme Snow Load Performance

Proyecto: Alpine Resort, Swiss Alps

Desafío: 400cm annual snowfall + 120mph winds

Solución SKW:

Métricas de rendimiento:

  • Sustained 290psf snow load (3× local code)
  • Zero deformation after 15 freeze-thaw cycles
  • Maintenance cost reduction: 75% vs traditional roofs

Thermal Load Management

Expansion Control Technology:

SKW Stone coated Metal Roof Expansion Control Technology

Movement Measurements:

Temp DeltaMovement per 10ftConventional RoofSKW System
100°F0.45″Buckling damageZero stress
150°F0.68″Seal failureControlled motion

Seismic Performance

Earthquake Simulation Data:

MagnitudeDisplacementResultado
6.0 Richter3.5″ lateralNo damage
7.2 Richter8.7″ lateralMinor clip deformation
8.0 Richter12.0″ lateralRepairable damage

Unique Feature:

  • Self-realigning clip system
  • Ductile steel deformation before failure
  • Non-brittle stone coating

Installation Load Considerations

Walking Safety System:

SKW  Walking Safety System

Load Distribution Technology:

  • Reinforced rib walking paths
  • Anti-slip granule technology
  • Point load spreader plates

Load Testing Methodology

Certification Process:

SKW Certification Process

Testing Equipment:

  • 400,000 lb hydraulic load frame
  • 8×8 ft wind tunnel nozzle
  • Accelerated weathering chamber

Structural Calculation Guidelines

Engineering Formulas:

SKW Engineering Formulas

SKW Performance Coefficients:

ParámetroValueVentaja
E (Elastic Modulus)203 GPa3× concrete
I (Moment of Inertia)0.89 in⁴/ft40% increase
Allowable Stress345 MPa28% higher

Degradation Factors:

  • Corrosion resistance maintains steel integrity
  • UV-stable coatings prevent embrittlement
  • Non-absorbent materials prevent freeze damage

Technical Documentation

Load Calculation Software

Certification Library

Structural Test Videos

Certifications: UL 580 • FM 4471 • ASTM E1592 • ICC-ES AC438 • CE EN 15601

SKW roofs are engineered to withstand nature’s most extreme forces – from Alaskan snow loads to Caribbean hurricanes. Our composite structural system delivers 2-3× the load capacity of traditional roofing, verified by independent laboratories and real-world performance in the world’s most demanding environments.

SU IDIOMA

Seleccionando su idioma podemos garantizarle el mejor servicio.