Attached SRI calculator+government subsidy application link+Madrid test video
1、 2024 European heatwave crisis and building energy consumption warning
1. Extreme high temperature data upgrade (latest report from the European Union Meteorological Agency)

Country | Number of Extreme High Temperature Days in 2023 | Peak Roof Surface Temperature | Increase in Air Conditioning Energy Consumption |
---|---|---|---|
Spain | 58 days>40 ℃ | 72 ℃ (asphalt shingles) | +41% |
Italy | 49 days>38 ℃ | 68 ℃ (concrete tile) | +37% |
Germany | 33 days>35 ℃ | 63 ℃ (ceramic tiles) | +29% |
2. The cost of traditional roof materials during thermal disasters
Munich Commercial Complex Case:
The use of dark asphalt shingles results in:
-Top floor office cooling cost: € 87000/year (exceeding 62%)
-The lifespan of the roof waterproof layer has been shortened to 5 years (normal 15 years)
■ SKW cold roof scheme saving calculation:
After switching to SRI 95 石材涂层金属屋顶:
-Air conditioning costs reduced by € 32000 per year
-Maintenance cycle extended to 22 years
2、 Core technology of cold roof: from reflective coating to structural innovation
1. Solar Reflectance Index (SRI) Technical Standard
–ASTM E1980-11 standard analysis:
SRI = 100×(α - 0.02) + 25.98×ε
(α: solar absorption rate, ε: thermal emissivity)
SKW cold roof parameters:
α=0.23,ε=0.86 → SRI=95
– EU Mandatory Certification Progress :
国家 | Minimum SRI Requirements | Effective Time | Penalty Standards |
---|---|---|---|
France | ≥ 82 | 2024.09 | Building permit rejected |
Spain | ≥ 78 | 2025.01 | Energy Efficiency Penalty € 30/m ² |
Netherlands | ≥ 75 | December 2024 | Property tax increases by 15% |
2. SKW CoolTech ™ Quadruple heat dissipation structure

- Reflective layer:
-Acrylic coating containing ceramic microbeads (reflectivity 92%)
-Anti pollution treatment: PM2.5 adhesion rate reduced by 67% - Insulation chamber :
-Air circulation channel design (wind speed ≥ 0.8m/s)
-Thermal resistance value R=4.5 (EN ISO 6946 standard) - Radiation layer :
-Aluminum zinc alloy substrate (thermal emissivity 0.86)
-3D concave convex surface increases heat dissipation area by 38% - Structural layer :
-Aluminum magnesium coated steel plate (yield strength 550MPa)
-Patent locking system (wind resistance 5.8kPa)
3、 Actual test data: Madrid vs Berlin Extreme Environmental Challenge
1. Berlin Winter Summer Comprehensive Test, Germany
-Annual Energy Consumption Monitoring Report:
Seasonal | Traditional roof energy consumption | SKW roof energy consumption | Energy saving rate |
---|---|---|---|
Summer | 158kWh/m ² | 92kWh/m ² | 41.8% |
Winter | 121kWh/m ² | 109kWh/m ² | 9.9% |
4、 EU Policy Dividend: Comprehensive Guide to Subsidies and Certification
1. Three step method for applying for government subsidies
- Prequalification:
-View the lists of energy agencies in various countries (such as ADEME in France and BAFA in Germany)
-SKW products have been pre registered in the EU EPD database (ID # SKW-EPD-2022-0765) - Document Preparation :
-Required materials:
◼ SRI testing report (EN 15804 standard)
◼ Installation of enterprise qualification certificates (such as RITE certification in Spain)
2. Authentication Acceleration Channel
-SKW Prefabricated Certification Package Service:
Service Content | Standard Cycle | SKW Acceleration Cycle |
---|---|---|
CE Mark (EN 50600) | 90 days | 45 days |
ACERMI certification in France | 120 days | 60 days |
Italian CAM certification | 75 days | 30 days |
5、 Tool Center and Successful Cases
1. Solar Reflectivity Calculator
– Operation Guide :
- 访问 https://skwroof.com/contact-us/
- 输入参数:
-Building GPS coordinates (automatically obtaining local meteorological data)
-Existing roof material - Obtain:
-Prediction of investment return rate for energy-saving renovation
-Recommended models for adaptation (including real-time inventory inquiry)
2. Record of Hamburg Business District Renovation in Germany
– Project Difficulties :
-Restrictions on the protection of historical buildings (prohibition of external insulation layers) -Must meet both DENA energy efficiency standards and aesthetic requirements simultaneously
-SKW Solution:
-Customized matte grey cold roof (SRI 89) -Integrated concealed photovoltaic tile (conversion efficiency 19.8%)
– Achievement Data :
指标 | 翻修前 | 翻修后 |
---|---|---|
Top floor room temperature fluctuation | ± 8 ℃ | ± 2 ℃ |
Air conditioning energy consumption | € 163000/year | € 97000/year |
Increase in building valuation | – | +18% |
6、 Immediate Action: Emergency Response Plan for Heatwave Season
1. Limited time discount package
-2024 Summer Special Service :
✅ Free thermal imaging testing (worth € 800)
✅ Government subsidy application service (reduced by € 1200)
✅ 48 hour express delivery (direct delivery from European bonded warehouse)
2. Technical Consultation Channel
-EU Engineer Direct Connection :
[WhatsApp Consultation]( +86 13153460330 )
[Email Contact] (mailto: business@skywalkerchina.com )